Locator 2.11 SR6 (2.11.875)

Build Number

Official build number: 2.11.875

Release Date

May 8th, 2020

License Compatibility

If you are upgrading from a previous ViaWorks 2.x release, your ViaWorks 2.x license will continue to work.  If you are installing Locator 2.11 SR6 for the first time, or if you are upgrading from ViaWorks 1.5.x, you will be required to obtain a new license key from ayfie.  Contact your ayfie sales representative to obtain your license key.

New Installations

Download the Locator Installation package, and run Locator_2.11.875.exe

For hardware and software requirements (including AV configuration information), and for help on how to install Locator, please see the Locator Installation Guide. 

Upgrading from a Prior Installation

You can upgrade to this release from a previous ViaWorks 2.x release.

You CANNOT upgrade to this release from ViaWorks 1.x or earlier.


If upgrading from a previous major version, it's recommended that you upgrade all installed connectors. If upgrading from 2.7 or below it's required that you upgrade all connectors.

 

Supervisor versions 2.1 and older do not support Locator 2.11 SR6. Customers should not upgrade to Locator 2.11 SR6 until they've upgraded to Supervisor 2.2. 
As Supervisor version 2.3 requires the new Authority Service, that comes with Locator 2.11 SR1 and above, users upgrading to Supervisor 2.3 should first upgrade to Locator 2.11 SR6.

Note: When you upgrade to Locator 2.11 SR6 you need to configure the Active Directory authentication system, as this is a requirement for Supervisor 2.3.

 

Notes if Upgrading from ViaWorks 2.7 or Older:

  • The PostgreSQL database format will be upgraded. It is strongly recommended to create a backup of the database prior to running the 2.11 upgrade. Once the database has been upgraded, it is not possible to revert back to a previous version

  • The index will be rebuilt after the upgrade has finished. The index rebuild can potentially take a while, and users may not be able to search or have incomplete search results until the rebuild completes. Documents will not be re-fetched during this process

  • All customers will be moved from the "ViaWorksV2" Solr core to the “ViaWorksCloud” Solr collection during the upgrade process. The “ViaWorksV2” core from versions 2.7 SR5 and older is no longer supported

  • During the upgrade, the solrconfig_overrides.xml and schema_overrides.xml files will be reset. Before upgrading, make note of the customization added to these files so they can be re-applied after the upgrade is complete. Note: the Solr schema has changed and overrides will need to be updated to support the changes.

  • Locator 2.11 SR6 will install .NET Framework version 4.7.2.

New Features & Improvements

Locator 2.11.875 is a new service release containing the following new features, bug fixes, and improvements

Improvements and Changes

Component

Description

Component

Description

Solr

Added new index field “platform_modified_by“.

Document Handler

SSL certificate has been updated.

Bug Fixes

Component

Description

Component

Description

Document Handler

Fixed an issue where nothing was logged if there was an error on service startup.

Licensing

Fixed an issue where license expire date was not updated when replacing an existing license.

 

ayfie